| General Specifications |
|
|
| Flow Range |
|
|
| Model |
: |
LS5576-2OOA |
| Nominal Size (mm) |
: |
40 |
| Flange Rating |
: |
JIS 10K RF |
| Flow Range , L/h |
|
|
| Kerosene |
: |
1200 to 11000 |
| (Above 0.8mPa•s to 2mPa•s) |
|
|
| Gas Oil (Heavy oil A) |
: |
600 to 14000 |
| (Above 2mPa•s to 5mPa•s) |
|
|
| Heavy Oil |
: |
400 to 14000 |
| (Above 5mPa•s to 200mPa•s) |
|
|
| |
|
|
| Meter Body |
|
|
| Acceptable flulds |
: |
Kerosene,Light oil,Heavy Oil (Not serviceable with gasoline) |
| Operating temp . Range (fluid temp.) |
: |
0 to 120⁰C |
| Max.operating pressure |
: |
1.18MPa |
| Linearity |
: |
±0.35% of RD |
| Material |
|
|
| Body |
: |
FC250 |
| Rotors |
: |
Special resin |
| Flow direction |
: |
Right → Left (standard),Left → right,bottom → top,top → bottom |
| Coating color |
: |
Orange : Munsell 2.5 YR 6/13 |
| |
|
|
| Mechanical Register Specifications |
|
|
| Model |
: |
LS5576 |
| Functions |
: |
Cumulative counter with dial-and-pointer,6 digits number wheels |
| Display |
|
|
| One pointer rev |
: |
10 L |
| Resolution |
: |
0.1L |
| Counter capacity |
: |
9,999,999.9L |
| Output Pulse |
: |
See next section |
| Operating Temp Range |
: |
-10 to +60⁰C |
| Construction |
: |
Waterproof conforming to IP 65 (weathertight) |
| Material |
: |
Resin/Alumunium die casting |
| Finish (houshing) |
: |
Munsell 4.9 PB4.0/13.9 (Color of molding) |
| |
|
|
| Factored Pulse generator in Mechanical Register (optional) |
| Item |
: |
MR sensor |
| Type of output pulse |
: |
Voltage pulse/open collector |
| Number of pulses (per pointer rev.) |
: |
10 P |
| Pulse Width |
: |
1 ms min |
| Duty factor |
: |
─ |
| Output Signal Levels |
: |
Voltage pulse ON:6.5V min OFF : 1 V max |
| |
|
Open Collector ON:1V max |
| Max.Operatiing Current |
: |
30mA |
| Max.Operating Voltage |
: |
40V DC (OPEN COLLECTOR) |
| Contact Bounce |
: |
─ |
| Life |
: |
─ |
| Signal Cable |
: |
Vinyl-insulated,4-conductor,shielded (core wire 0.5mm²,4 to 10mm in O.D) |
| Transmission Distance |
: |
1 Kilometer max.(using a CVVS cable 1.25 to 2.0mm²) |
| Power |
: |
12 to 24VDC ±10% |
| Current Drain |
: |
20mA max |
| |
|
|
| Item |
: |
Reed switch |
| Type of output pulse |
: |
Contact-closure pulse |
| Number of pulses (per pointer rev.) |
: |
1 P |
| Pulse Width |
: |
─ |
| Duty factor |
: |
40/60 to 60/40 |
| Output Signal Levels |
: |
─ |
| Max.Operatiing Current |
: |
60mA (200Ω protective resistor provided) |
| Max.Operating Voltage |
: |
125V AC,50V DC |
| Contact Bounce |
: |
0.5ms max |
| Life |
: |
5 x 10⁷ cycles off operating (with resistive load at 12V DC,10mA) |
| Signal Cable |
: |
Vinyl-insulated,4-conductor,shielded (core wire 0.5mm²,4 to 10mm in O.D) |
| Transmission Distance |
: |
1 Kilometer max.(using a CVVS cable 1.25 to 2.0mm²) |
| Power |
: |
─ |
| Current Drain |
: |
─ |
| |
|
|
| Mechanical Register Pulse Output |
|
|
| Model |
: |
LS5576-2OOA |
| Nominal Size (mm) |
: |
40 |
| MR Sensor |
|
|
| Pulse Units |
: |
1 L/P |
| Pulse Units at Max Flow Rate |
: |
3.8 Hz |
| Reed Switch |
|
|
| Output Freq |
: |
10 L/P |
| Pulse Units Output Freq |
: |
0.38 Hz |
| at max Flow Rate |
|
|
| Max Flow Rate (L/h) |
: |
14000 |